Still blowing cold
Defrost cycles keep running long, the strips keep kicking on, and your bill keeps climbing while the air out of the vents stays cool more than it should.
Get matched with a pro who works on heat pumps in Linn County.
Get matchedA heat pump blowing cold air usually means it's stuck in defrost or running on the backup heat strips while it thinks it's defrosting, and in a hard Iowa winter that cycle can run longer and more often than it would somewhere milder. It can also mean the system has switched to cooling by mistake, often just a thermostat setting, or that the reversing valve that switches it between heating and cooling has failed. A heat pump does push air that feels cool to the hand even when it's working right, since the air coming out is well below your skin temperature but still warmer than the room. If the air feels truly cold, not just cool, and your house isn't warming up, something is off. Low refrigerant, a failing compressor, or a stuck reversing valve are the common causes, and none of them get better on their own.

A heat pump pulls heat from outside air, and in cold weather frost builds on the outdoor coil. The system runs a defrost cycle to clear it, reversing briefly so the outdoor coil gets warm while the indoor side keeps circulating air. During that reversal, the air coming out of your vents will feel cool or even cold for a few minutes. That part is normal. The problem is when it won't switch back.

If the heat pump gets stuck thinking it needs to defrost, or the outdoor unit can't finish clearing itself, the backup heat strips are what's supposed to carry the load in the meantime. In Linn County winters, with outdoor temperatures low for weeks at a stretch, those strips can end up running far more than they're built for, and a weak strip or a bad control board will leave you with air that never warms back up.
Winter nights average 15°F
Nights average 15°F here in December and January. That's cold enough for frost to build fast on the outdoor coil, so defrost cycles kick in often.
Heat runs October through May
Heat runs here from October through May. A heat pump stuck cycling into backup heat strips that whole stretch adds up on an electric bill fast.
Cooling runs June through August
Cooling only runs here June through August. The other eight months, any time it blows cold, it's the heating side acting up, not the AC.
NOAA nClimDiv 1991-2020
A heat pump in good shape still blows cool air for a few minutes during a normal defrost cycle, then switches back and the air coming out warms up again. If your thermostat is set to "emergency heat," the heat pump shuts off completely and the backup strips do all the work, so the air should come out warm the whole time, not cold.
If the air stays cool for longer than a defrost cycle, or the outdoor unit is iced over and never seems to clear, or the system runs on emergency heat and the air is still cold, something is wrong. At 15°F outside, a heat pump that can't shift back to heating after defrost will lose ground fast, and the backup strips alone may not keep up on the coldest nights.




Send the request today and stop worrying about who to call.
No charge to send it. You decide if you hire them.
The backup heat strips that kick in during defrost don't work like a heat pump. They're closer to a toaster, drawing a lot of power to make heat directly, and power here isn't cheap. If your system is cycling into defrost often, or getting stuck there, those strips are running more than they should, and you'll see it on the bill before you figure out why. A system that's defrosting every twenty minutes through a stretch of single-digit nights is spending a lot more on backup heat than one that defrosts the way it's supposed to, a few times an hour at most, and switches back to normal heating in between.
A heat pump that's stuck blowing cold air isn't just uncomfortable. If the outdoor coil is icing up and not clearing, ice can build past what a normal defrost cycle handles, and that puts strain on the compressor, the part that's expensive to replace. The backup strips can carry the house for a while, but they're not meant to be the main source of heat all winter. If your thermostat is set to emergency heat and the heat pump itself isn't running at all, nothing is left pulling heat from outside, and you're paying full price for all of it through strip heat alone.


Defrost cycles keep running long, the strips keep kicking on, and your bill keeps climbing while the air out of the vents stays cool more than it should.
A contractor finds why defrost won't let go or why the strips won't shut off, and the heat pump goes back to heating the way it's supposed to.

A heat pump that keeps blowing cold air in a Cedar Rapids winter is telling you something specific: defrost is running too long, the strips aren't picking up like they should, or the system has lost refrigerant it needs to move heat at all. None of those sort themselves out. The cold nights that make defrost necessary in the first place are the same nights you need the heat to actually work.
A contractor who looks at your system can tell you which of those it is and what it takes to fix it. Once you send the form, that part isn't on you anymore. You'll be matched with a contractor who handles heat pumps like yours and hears from them directly, so you're not the one calling around Linn County trying to find someone who can look at it this week.


A heat pump pro near you