Can a heat pump keep up with a Buchanan County winter
Your furnace or heat pump here runs eight months a year, October through May, and the overnight low averages 13°F across December, January and February. That is well below the two marks that matter for a heat pump. Below 40°F a standard heat pump puts out less than its rated heating capacity. Below about 35°F it often needs backup heat to make up the difference. At 13°F average, and on the roughly 155 nights a year here that fall to freezing or below, a standard heat pump is working below both marks most of the heating season.
That does not mean a heat pump leaves you cold. Cold climate models, the ones carrying the ENERGY STAR Cold Climate mark, are built and tested to still make 1.75 units of heat for every unit of electricity at 5°F, and to hold onto at least 70 percent of their 47°F capacity at that temperature. In a two winter field test of prototype cold climate heat pumps in occupied homes, backup heat covered only a small share of the heat needed between 0°F and 35°F, and the homes rarely ran on backup heat alone even above 0°F. About 20 nights a year here reach 0°F or below, under a quarter of the nights that hit freezing. A cold climate heat pump sized and installed for this county can carry most of the season on its own. A standard one will lean on its backup far more often, on more than half the nights the heat runs here.