What the cold does to a heat pump here
Winter here is long and it bites. Heat runs about eight months a year, October through May, and the overnight low averages 12°F across December, January and February. That's not a mild climate with a few cold snaps. More than half the nights in heating season, about 155 of them, drop to freezing or below. About 25 nights a year hit 0°F.
A standard heat pump starts losing ground before it even gets that cold. Below 40°F its heat output falls short of what it's rated for. Below about 35°F it often needs backup heat to keep up. The average winter night here is 12°F, well past both of those marks, and every single night at or below freezing is past them too. This isn't an occasional dip into territory a heat pump struggles with. It's where this county's winter lives.
That doesn't rule a heat pump out. Cold climate models carry a separate rating for this: to earn the ENERGY STAR Cold Climate label, a heat pump has to keep at least 70 percent of its 47°F capacity at 5°F, tested by someone other than the manufacturer. A field test of prototype cold climate heat pumps over two winters found backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. So the newer equipment handles a night like the ones this county gets regularly. A furnace built to the federal minimum, the kind the running cost above is based on, does not.