What winter here does to a heat pump
Your furnace, if you go that way, runs about eight months a year here, October through May. That's the season that decides this, not summer. Winter nights average 20°F, and about 115 nights a year drop to freezing or below. A standard heat pump starts losing ground before it even gets that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it usually needs backup heat to keep up. Both of those marks sit above our average winter low, and every single one of those 115 freezing nights falls below both.
That doesn't mean a heat pump quits. On the roughly 8 nights a year that reach 0°F, a cold-climate model, one certified to hold at least 70 percent of its capacity and still produce 1.75 units of heat per unit of electricity at 5°F, is built for exactly that. Field testing on prototype cold-climate units backs this up: backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even at 0°F. So if a heat pump goes in here, it should be a cold-climate model, not the standard kind, and most houses will still want a backup heat source for the handful of coldest nights.