What the cold does to a heat pump here
The heat runs eight months a year here, October through May, and the overnight low averages 16°F across December, January and February. That is the climate a heat pump has to work in, not a mild one.
A standard heat pump's heat output falls short of its rating once it drops below 40°F, and below about 35°F it often needs backup heat to keep the house warm. About 135 nights a year here fall at or below freezing, over half the nights that the heat even runs, and every one of them sits below both marks.
Twelve nights a year reach 0°F or below. That is a small share of the 135 freezing nights, but it is where a standard heat pump is weakest, putting out only a fraction of its rated heat. A heat pump built to the ENERGY STAR Cold Climate mark is tested differently: it has to make at least 1.75 units of heat per unit of electricity at 5°F and still hold 70 percent of its 47°F capacity at that temperature. In field tests of prototype cold-climate heat pumps running in occupied homes over two winters, backup heat covered only a small share of the heat needed between 0°F and 35°F, and running on backup alone was rare even above 0°F.
A furnace does not have this problem at all. It burns gas and makes full heat whether it is 30°F out or 12 below.