What 10 degrees does to a heat pump
Winter here settles the question before cost does. The average overnight low from December through February is 10°F, and a standard heat pump starts losing ground well above that. Below 40°F it puts out less heat than its rating says. Below about 35°F it usually needs backup heat to keep up. The average night here is below both marks, and so is every one of the roughly 155 nights a year that drop to freezing or colder.
That is over half the nights in the eight months your heat runs, from October through May. On about 25 of those nights the temperature falls to 0°F or below, and that is where a standard heat pump is working hardest and producing the least. A furnace does not have this problem. It burns gas to make heat, so outdoor temperature does not touch its output. On a 0°F night it heats the same as it does at 30°F.
None of this rules a heat pump out. It means the heat pump that works in this house has to be a cold climate model, not the standard one the running costs above are based on. To carry the ENERGY STAR Cold Climate label, a heat pump has to deliver at least 1.75 units of heat per unit of electricity at 5°F and hold onto 70 percent of its 47°F capacity at that temperature, verified by outside testing, not just claimed. In a two winter study of these cold climate units in real homes, backup heat covered only a small share of the load between 0°F and 35°F, and running on backup heat alone was rare even at 0°F. That is a different machine than the one priced above.