What the cold here does to a heat pump
Winter here is long and it gets hard cold. Heat runs about eight months a year, October through May, and the overnight low averages 12°F across December, January and February. About 155 nights a year dip to freezing or below, and about 20 of those reach 0°F or below.
A standard heat pump starts losing ground before it even gets that cold. Below 40°F it puts out less heat than its rating says, and by the teens that gap is wide. Below about 35°F it typically needs backup heat to make up the difference. Your average winter night here, 12°F, is below both marks, and every single one of the 155 nights at or below freezing is too. This is not a cold snap a few times a season. It is most of the winter.
That does not rule out a heat pump. ENERGY STAR's Cold Climate models are built for exactly this, holding at least 1.75 units of heat per unit of electricity at 5°F and keeping most of their rated output at that temperature, tested by an outside lab. Field testing on prototypes of these machines over two winters found backup heat carried only a small share of the load between 0°F and 35°F, and the machines rarely ran on backup alone unless it dropped below 0°F. If you are set on a heat pump here, this is the version to ask for, not the standard one.