Eight months of work a year
Furnaces in Maquoketa run from October through May. Overnight lows average 16°F through December, January and February. That's a long stretch of cold for a furnace to answer to, and it doesn't let up once it starts.
Takes about a minute. No obligation.
Furnaces in Maquoketa run from October through May. Overnight lows average 16°F through December, January and February. That's a long stretch of cold for a furnace to answer to, and it doesn't let up once it starts.
Eight months of runtime a year puts real hours on an igniter, a blower motor, the parts that do the work every time the furnace cycles on. Those parts wear sooner under that kind of load, and a weak one tends to give out once the cold settles in for good.
Half the homes in Jackson County were built in 1970 or earlier.
A furnace that old needs eyes on it every year, before a worn part fails in the cold.



Gas heats more homes in Jackson County than anything else, 54.1 percent, and most of the rest run on LP gas. That means most furnaces in this area are burning fuel to make heat, not just moving it with electricity. A gas furnace draws combustion air in and sends exhaust out through a vent, and both have to stay clear and sealed right for the furnace to run safely. A technician checks the burner flame, the heat exchanger, the vent pipe and the gas pressure, not just the filter and the thermostat. A cracked heat exchanger or a blocked vent won't announce itself the way a dead blower motor will. That's the kind of problem a yearly check is built to catch before the furnace runs on it all winter.
It works hard here, so worn parts show up fast once the season starts. Get it checked before then.
Find a contractor
A yearly check is what catches a worn part before it fails on the furnace. If your furnace came with the house, have someone look at it every year, not just when something seems off.
The flame sensor tells the control board the burner lit. Soot builds up on it over time, and once it's coated thick enough, it stops reading the flame at all. The furnace shuts itself off a few seconds after ignition, over and over, and the house goes cold with no warning first.
When a filter packs with dust, the blower motor has to pull harder to move the same air. That strain shortens the motor's life, and the heat exchanger behind it runs hotter than it should. Replacing a filter is simple. Catching what a year of running dirty already did to the motor is not.
A quick visit checks that the furnace turns on and blows warm air, then calls it done. A thorough one opens the cabinet and looks at what made that air. That means pulling the burner cover to look at the flame, which should burn steady and blue, not yellow or lifting off the burner. It means checking the heat exchanger for cracks, since a cracked one can let exhaust mix into the air the furnace is heating. It means testing the gas pressure against what the furnace is built to run on, not assuming it's still set right. A tune-up that skips these and goes straight to the filter and thermostat isn't wrong, it's just not finished.
The blower compartment is worth opening too, not just the burner side. A tech will pull the panel and look at the wheel itself, since dust cakes onto the blades over time and throws the wheel out of balance. An unbalanced wheel wears its bearings faster and moves less air for the same effort, even when the motor sounds fine. The same visit usually checks the belt or coupling where the motor meets the wheel, if the furnace has one, for cracking or slack. Wiring at the control board gets a look as well, since a loose connection can cause the exact short-cycling a dirty flame sensor does, for a different reason entirely. None of this shows up by watching warm air come out of a vent.