Gas heats most homes here
Utility gas heats 67.5% of occupied homes in Des Moines County. Electricity comes in a distant second at 19.4%, with LP gas making up most of the rest.
Takes about a minute. No obligation.
Utility gas heats 67.5% of occupied homes in Des Moines County. Electricity comes in a distant second at 19.4%, with LP gas making up most of the rest.
A house built around a gas furnace wasn't set up with heat pump operation in mind. Installing one means the contractor sizes the equipment for this house and this ductwork, not a like-for-like swap.

NOAA nClimDiv, 1991–2020 normals
Half the homes in Des Moines County were built in 1959 or earlier.
A heat pump going into a house that age has to be sized for the ductwork and rooms already there, not the other way around.



A heat pump here doesn't need to be oversized or top of the line to do the job. Iowa homes paid 13.40 cents per kilowatthour in 2024. A unit matched to the house runs on the electricity it actually needs, nothing more. Going bigger than the house calls for doesn't heat it faster. It just cycles on and off more and costs more to run. The contractor sizing your system will work from the square footage, the ductwork, and the rooms you have, not from a bigger-is-safer guess.
Heat here runs October through May, eight months out of the year. Get a new system in before September and it's set, tested, and running right by the time you need it. Wait until the first cold morning and you're choosing equipment under pressure instead of on your own timeline.
Find a contractor
December through February, the overnight low here averages 19°F. That's the load a heat pump has to cover on the coldest nights, not just the mild stretches in spring and fall. A unit sized for this place runs on standard equipment built for zone 5A cold. Nothing about Des Moines County pushes a system past that.
A heat pump replaces both halves of the system. The gas furnace gets disconnected and removed, and so does the outdoor AC condenser if there was one. The gas line that fed the furnace gets capped off by whoever handles that part of the job. None of it stays in place as a backup unless that's planned for ahead of time.
If the existing ducts are in sound shape, the contractor connects the new heat pump to them rather than running new ductwork. The old thermostat usually gets swapped too, since heat pumps need a thermostat built to control heating and cooling from one unit. What stays is the path air already moves through the house, not the equipment that was pushing it.
Sizing a heat pump starts with a load calculation, not a guess based on the old equipment's label. The contractor measures the square footage, checks insulation, counts windows, and looks at ceiling height in every room, then works out how much heat the house actually loses on a cold night and how much it gains on a hot afternoon. That number, not the size of the unit it's replacing, drives the equipment choice. Too small and it runs flat out without catching up on the coldest days. Too big and it satisfies the thermostat fast, shuts off, then starts again a few minutes later. That short cycling wears on the compressor and leaves rooms feeling clammy, because the unit never runs long enough to pull moisture out of the air. The right size runs longer, steadier stretches, which is what actually keeps a house comfortable.
Installation day starts with the outdoor unit and the indoor coil, not the thermostat on the wall. The crew sets the new outdoor unit on its pad, runs the refrigerant lines to the indoor coil, and ties into the ductwork that's already there. Electrical work usually means a new circuit or breaker sized for the heat pump, since it draws differently than the old furnace and AC did. Once it's connected, the line set gets pressure tested and then evacuated to pull out air and moisture before refrigerant goes in. A system charged without that step can run fine for a while and still fail early. After the charge is set, the contractor checks airflow at the vents, confirms the thermostat is talking to the equipment correctly, and runs the system in both heating and cooling to see that it responds the way it should.
