What the cold here does to a heat pump
Winters here decide this. The heat runs about eight months a year, October through May, and the overnight low averages 19°F in December, January and February. That's not a mild climate with a few cold snaps. About 120 nights a year drop to freezing or below, roughly half the nights in the heating season, and a standard heat pump starts losing ground well above that mark. Below 40°F it puts out less heat than its rating says. Below about 35°F it typically needs backup heat to make up the difference. Nineteen degrees is under both marks, and so is every single one of those 120 freezing nights.
That doesn't mean a heat pump quits. About 8 nights a year here reach 0°F or below, a small slice of the season, and even in cold-climate field testing, backup heat covered only a small share of the output between 0°F and 35°F. Running on backup alone was rare except on the hardest nights. But that testing was done with ENERGY STAR Cold Climate models, built to hold 70 percent of their 47°F output at 5°F and still produce 1.75 units of heat per unit of electricity at that temperature. A standard heat pump, built to the federal minimum, is not that machine. If a heat pump is the choice here, that distinction is the one worth checking before buying.
A furnace has none of this fall-off. Its output doesn't change with the temperature outside. On the coldest night of the year it heats the same as it does in October.