Gas heats most homes in Poweshiek County
Utility gas heats 45.3% of occupied homes here, more than any other fuel. Electricity comes next at 25.6%, with LP or propane close behind at 25.0%.
Takes about a minute. No obligation.
Utility gas heats 45.3% of occupied homes here, more than any other fuel. Electricity comes next at 25.6%, with LP or propane close behind at 25.0%.
If your home runs on gas now, a heat pump install means weighing it against a furnace rather than swapping in an identical unit. Some homeowners keep the furnace for the coldest days and let the heat pump handle the rest.

NOAA nClimDiv, 1991–2020 normals
A heat pump installed in Grinnell runs cooling first, from June through August, then switches over when heat starts in October.
Get it in before September and it has a full summer to run before it has to carry you through the cold months.



Poweshiek County falls in zone 5A, a cool climate where heating carries the bigger load. Any split-system heat pump installed here has to meet federal minimums of 14.3 SEER2 for cooling and 7.5 HSPF2 for heating. That sets a floor for what a contractor can install, and a federal tax credit is available on top of it.
Find a contractorHalf the homes in Poweshiek County were built in 1971 or earlier. A house that age wasn't built with a heat pump in mind, and the ductwork or electrical panel may still reflect that. A contractor sizing your install has to work with what's actually there, not a generic load calculation. If your ducts were set up for a gas furnace running hot air, they may need a look before a heat pump moves cooler air through them for heating. Worth having that checked before the unit goes in, not after.
A contractor works out heat pump size room by room, using window area, insulation, ceiling height and air leakage, not by matching whatever is out there now. The system before yours may have been wrong from day one, sized off a rule of thumb or bumped up to be safe. Carrying that mistake forward just repeats it.
A heat pump too big cools or heats the air fast and shuts off before it pulls moisture out, so the house feels clammy even at the right temperature. One too small runs constantly on the coldest and hottest days and never quite catches up. Right-sized, it runs long steady cycles that hold the temperature even and keep humidity in check.
If a furnace is coming out to make room for the heat pump, the old unit and its ductwork connections get disconnected and hauled off, and the gas line serving it gets capped off by whoever is qualified to do that, not left live and unused. A gas furnace getting pulled out entirely needs that line capped properly, which is a separate job from the electrical work the heat pump itself needs. If the plan is to keep the furnace as backup for the coldest days, none of that applies. It stays in place, still tied into the ducts, and the heat pump gets added alongside it rather than in place of it. Either way, the old thermostat usually comes out too, since a heat pump needs one built to manage both heating and cooling modes and the defrost cycle in between.
Install day starts with the outdoor unit and the indoor coil, set in place and connected by refrigerant lines that run between them. Those lines get checked for leaks before anything is charged, since a joint that isn't sealed right will show up as lost performance months later rather than that same day. The electrical work usually takes as long as the mechanical part, since a heat pump draws power the old furnace never needed and the panel may need a new circuit to carry it. Once everything's connected, a contractor runs the system through both modes, heating and cooling, checking the refrigerant charge against what the manufacturer specifies for that line length. That charge has to be exact. Too little and the system struggles on the coldest days, too much and it can damage the compressor over time. The last step is usually the thermostat, programmed and tested through a full cycle before anyone calls the job done.