What the cold here does to a heat pump
The heat runs eight months a year in Poweshiek County, October through May, and the average overnight low across December, January and February is 15°F. About 150 nights a year drop to freezing or below. Eighteen of those get down to 0°F or colder.
A standard heat pump starts losing ground before it gets anywhere near that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it typically needs backup heat to make up the difference. The average winter night here is already past both marks, and every one of the 150 nights at or below freezing is too.
That doesn't mean a heat pump can't heat your house here. Cold climate models carry a separate rating built for this: to earn the ENERGY STAR Cold Climate label, a heat pump has to keep at least 70 percent of its 47°F capacity at 5°F, and still make at least 1.75 units of heat per unit of electricity at that temperature, checked by independent testing. Field tests of these units in occupied homes found backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. So the real choice here is a furnace against a cold climate heat pump. A standard one is not built for 18 nights at 0°F.