What winter here does to a heat pump
Your heat runs eight months a year in Carroll County, October through May, and the overnight low averages 14°F across December, January and February. That is below both marks that matter for a heat pump. A standard heat pump starts falling short of its rated heat output once it is below 40°F outside, and below about 35°F it often needs backup heat to keep up. Fourteen degrees is under both marks, and so is every one of the about 155 nights a year here that drop to freezing or below, over half the nights the heat is even running.
That does not mean a heat pump quits in the cold. Models carrying the ENERGY STAR Cold Climate label are tested to hold at least 70 percent of their 47°F heating capacity down at 5°F, and to still make 1.75 units of heat for every unit of electricity at that temperature. A two-winter field test of prototype cold-climate heat pumps in occupied homes found backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. Carroll County sees about 18 nights a year at 0°F or below, under a quarter of the nights that reach freezing. A standard heat pump here will lean on backup heat often. A cold climate one, sized for this weather, will lean on it rarely.