What a heat pump runs into here
Winter here is the whole question. Heat runs eight months a year, October through May, and the overnight low in December, January and February averages 17°F. That's not a cold snap, that's the normal night. A standard heat pump starts losing ground before it even gets that cold. Below 40°F it already puts out less heat than its rating says. Below about 35°F it typically needs backup heat to keep up. The average low here sits under both marks, and every single night at or below freezing does too, and that's about 140 nights a year, over half the nights the heat is running.
None of that means the house goes cold. It means a standard heat pump spends most of the winter leaning on backup heat to make up the difference, and that backup heat is almost always electric resistance, the most expensive way to heat a house. Fourteen nights a year drop to 0°F or below. A cold climate heat pump, the kind certified to hold at least 1.75 units of heat per unit of electricity at 5°F and keep most of its capacity down there, handles those nights far better than a standard model. Field testing on prototype cold climate units found backup heat covering only a small share of the output between 0°F and 35°F, and the unit running on backup alone was rare even at 0°F. That's a different machine than the one priced in the running cost comparison above, which assumes no backup at all.