Can a heat pump keep up with winter here
Heat runs eight months a year here, October through May, and the overnight low averages 12°F across December, January and February. That number is the whole question. A furnace built to the federal minimum makes its full rated heat whether it's 30 above or 10 below. A standard heat pump does not.
A standard heat pump's heat output falls short of its rating once it's below 40°F outside, and below about 35°F it often needs backup heat to keep the house warm. About 160 nights a year here fall to freezing or below, and every one of them is colder than both of those marks. That's over half the nights in the heating season, not just the hard cold snaps.
About 25 nights a year drop to 0°F or below, under a quarter of the freezing nights. That's where a standard heat pump leans hardest on backup heat. A furnace has nothing like this problem at any temperature on the list.
There is a different kind of heat pump built for this. One carrying the ENERGY STAR Cold Climate label is tested to make at least 1.75 units of heat for every unit of electricity at 5°F, and to hold onto at least 70 percent of its 47°F capacity at that same temperature, verified by outside testing, not the maker's word. A two-winter field test of prototype cold-climate heat pumps in occupied homes found backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. That is a different machine than the standard, federal-minimum heat pump behind the cost comparison above.