What winter here does to a heat pump
Your winter decides this. The average overnight low across December, January and February here is 17°F. A standard heat pump starts falling short of its rated output below 40°F and often needs backup heat below about 35°F. An average night here is below both marks.
That's not a few bad nights. About 135 nights a year here drop to freezing or below, more than half of the roughly 245 nights across the eight months your heat runs. Every one of those nights sits below the 40°F and 35°F marks. Only about 13 nights a year reach 0°F or lower, so most of your cold is the long stretch in the 20s and teens, not the rare deep freeze.
A heat pump built to the ENERGY STAR Cold Climate mark is built for that stretch. To earn the label it has to produce at least 1.75 units of heat for every unit of electricity at 5°F, and hold onto at least 70 percent of its warm-weather capacity at that same temperature, checked by outside testing. A two-winter field test of prototype cold-climate heat pumps in occupied homes found backup heat covered only a small share of the load between 0°F and 35°F, and the units ran on backup alone only rarely, even near 0°F. A furnace-grade heat pump was not built for a winter shaped like yours. A cold-climate one was.