What cold nights do to a heat pump here
Winter in Dallas County is the real question, because heat runs eight months a year here and cooling only three. Whatever you pick will spend most of its life heating this house, not cooling it.
A standard heat pump starts losing ground before it gets truly cold. Below 40°F its heat output drops under its rating, and below about 35°F it typically needs backup heat to make up the difference. The average overnight low here in December, January and February is 15°F. That is not an edge case. That is the winter.
Count the nights. About 140 nights a year here drop to freezing or below, more than half of the roughly 245 nights the heat is running. Every one of those nights sits below both the 40°F and 35°F marks. About 15 nights a year reach 0°F or below, and on those nights a standard heat pump is leaning hard on its backup heat to keep the house warm.
Cold climate heat pumps close part of that gap. To carry the ENERGY STAR Cold Climate label, a heat pump has to keep at least 70 percent of its 47°F capacity at 5°F and still produce 1.75 units of heat per unit of electricity at that temperature. Field tests of prototype cold climate models in occupied homes found backup heat covering only a small share of the output between 0°F and 35°F, and running on backup alone was rare even above 0°F. That is a different machine than the federal-minimum unit priced in the running cost band above, and it is worth asking any contractor whether the heat pump they are quoting carries that rating.